IEC 60097 PDF

Explosive atmospheres - Part Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC E gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment by pressurization or artificial ventilation or both as applicable when located in an explosive gas atmosphere or combustible dust atmosphere hazardous area with or without an internal source of a flammable gas or vapour. It also includes a room located in a non-hazardous area that has an internal source of release of a flammable gas or vapour. This document deals with rooms that are partially constructed in a manufacturer s facility and intended to have the final installation completed on-site, as well as rooms that are constructed completely on-site. Rooms partially constructed in a manufacturer s facility may include third-party verification.

Author:JoJolkis Bradal
Country:French Guiana
Language:English (Spanish)
Genre:History
Published (Last):2 July 2014
Pages:189
PDF File Size:18.93 Mb
ePub File Size:15.95 Mb
ISBN:420-3-62485-398-6
Downloads:79608
Price:Free* [*Free Regsitration Required]
Uploader:Kazigal



Explosive atmospheres - Part Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC E gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment by pressurization or artificial ventilation or both as applicable when located in an explosive gas atmosphere or combustible dust atmosphere hazardous area with or without an internal source of a flammable gas or vapour.

It also includes a room located in a non-hazardous area that has an internal source of release of a flammable gas or vapour. This document deals with rooms that are partially constructed in a manufacturer s facility and intended to have the final installation completed on-site, as well as rooms that are constructed completely on-site. Rooms partially constructed in a manufacturer s facility may include third-party verification.

For rooms built on-site, this document can be used by plant operators as a guide for assessment of those facilities. This document represents a major technical revision of the requirements for equipment protection by pressurized room p and artificially ventilated room v and should be considered as introducing all new requirements.

This second edition cancels and replaces the first edition published in This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - modification of the title of this document to include artificially ventilated room v in addition to pressurized room p ; - addition of types of protection pb , pc , and vc and removal of types of protection px , py , pz and pv ; - definition of the differences between pressurization and artificial ventilation types of protection; - removal of protection of rooms with an inert gas or a flammable gas from the scope of this document; - addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines.

Additional information regarding the scope of this document can be found in Clause 1. Keywords: marking of rooms used to protect internal equipment, pressurized room p , artificially ventilated room v.

JAMES BACQUE OTHER LOSSES PDF

Standards Documentation for Purchase

Preview Abstract IEC specifies the requirements for the design, construction, testing and marking of electrical equipment and Ex Components with type of protection increased safety "e" intended for use in explosive gas atmospheres. Level of Protection "eb" applies to equipment or Ex Components, including their connections, conductors, windings, lamps, and batteries; but not including semiconductors or electrolytic capacitors. Level of Protection "ec" applies to equipment or Ex Components, including their connections, conductors, windings, lamps, and batteries; and also including semiconductors and electrolytic capacitors. The requirements of this standard apply to both Levels of Protection unless otherwise stated. For Level of Protection "eb", this standard applies to electrical equipment where the rated voltage does not exceed 11 kV r.

BT149B DATASHEET PDF

Popular Publishers

Nelmaran Special materials of construction had to be selected in order that the pump ie capable of pumping liquids containing solids and the Oil Sands Mines have purchased on average two pumps every year and there are currently 23 pumps in operation. Please first log in with a verified email before subscribing to alerts. You may delete a document from your Alert Profile at any time. Would you like to tell us about a lower price? If the document is revised or amended, you will be notified by email. Shopbop Designer Fashion Brands. As the voice of the U.